Home>mall>Electronics
0Liked

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

4.6
★★★★★
33
$10.99 /$13.41
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$2.20 /$13.41

Guaranteed Safe Checkout

Free Gift
Free gift with any purchase
Shipping Policy
Free standard shipping on orders over $9.9
Return Policy
Return items will be accepted within 40 days when is the date of receiving the goods. Customized items cannot be returned or exchanged. Items bought with an e-gift card are exchangeable only; refunds are not applicable.

Free Gift

Welcome to Roymall, your professional website for purchasing premium department store gifts. We highly value and appreciate your support, and we want to express our gratitude by adding an extra touch of excitement to your purchases. When you shop with us, you not only get to enjoy high-quality products that enhance your lifestyle, but you'll also receive an exclusive free gift with every order you place. Ready to explore our collection and find your perfect gifts? Browse our selection of premium department store items, place your order, and look forward to the excitement of your free gift arriving alongside your purchase.

Shipping Policy

We will work hard to deliver items to you after receiving your orders and make sure they arrive safely. Delivery details will be provided in your confirmation email.In most cases, orders are processed within 2 days.Under special circumstances, it will be delayed as follows: When you place an order on Saturday, Sunday or public holidays, it will be delayed for 2 days..Normally, it needs 5-7 working days (Monday to Friday) without being affected by flight delay or other environmental factors..Because our shipping service is worldwide so the delivery times will depend on your location so it may need a few times and please wait patiently if you are in remote districts or countries.

1. Return & Exchange Policy

We only accept items purchased from roymall.com. If you purchase from our local distributors or other retailers, you cannot return them on our side. Final sales items or free gifts are not acceptable for a return. To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.After receiving return instructions from us, please package up your returned items and drop your package at the local post office or another courier.
We will process your return or exchange item within 3-5 working days after we receive it. The refund will be processed and credited automatically to your original method of payment.No returns or exchanges can be accepted if the product was custom produced, including custom size, custom color, or custom printed.Need more help, please contact us. service@roymall.com or Whatsapp: +8619359849471

2.Refund Policy

You'll get a full refund or 100% store credit after we receive the returned package and check it. The refund will be processed and credited automatically to your original method of payment. Please note that shipping costs and any duties or fees are not refundable. The extra shipping costs are non-refundable once the package has been shipped. You are responsible for paying these fees and we’re unable to waive or refund them, even if the order is returned back to us.Once we received and confirmed your returned item, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.If you have any problems regarding the refund process, please contact us. service@roymall.com or Whatsapp: +8619359849471

Specifications:


1: Power supply voltage: DC6--40V, voltage detection range DC 0--60V, suitable for less than 60V of the various batteries, voltage measurement error u00b1 0.1V.

2: charge and discharge time (OP) range: 0 - 999 minutes.



Features:


1. Battery charge and discharge intelligent control

2. You can set the charge and discharge time

3. With serial communication function, real-time monitoring of the working status of the relay through the serial port

4. Additional signal output, when the relay to meet the conditions, the output high, you can control other equipment

5. A key emergency stop function (STOP button), with reverse protection, reverse does not burn



Operating mode:


Voltage upper limit: UL1, voltage lower limit nL1, the voltage upper limit is greater than the voltage lower limit (UL1> nL1)

U-1: Charging measurement: When the measured voltage is lower than the lower limit voltage, the relay pulls above; the upper limit voltage, the relay is disconnected.

U-2: Charge measurement time control: set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage is higher than the upper limit voltage , The relay is disconnected.

U-3: Discharge detection: When the measured voltage is lower than the lower limit voltage, the relay is off, above the upper limit voltage, the relay pulls.

U-4: Discharge detection time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected.

U-5: Voltage in the range, the relay pull: when the measured voltage between the upper and lower limits, the relay pull, the other circumstances open.

U-6: Voltage outside the interval, the relay pull: the measured voltage below the lower limit voltage or higher than the upper limit voltage, the relay pull, the other case the relay is off.



How to set parameters:


1. First, according to their needs, to determine the requirements of the work model;

2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current mode of operation, the default U-1 mode, and then enter the main interface) press the SET button for 2 seconds and then release, enter the selection Mode interface, UP, DOWN button to select the mode to be set (U-1 ~ U-6);

3. After selecting the mode, assume that we have selected the U-1 mode and press the SET button to set the corresponding parameter. The parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), press UP, DOWN Key to increase or decrease, you can always press the key to quickly increase or decrease, press the SET button to set the current mode of the next parameter, the process above;

4. Set the parameters, and then press the SET button for 2 seconds to release, the current setting mode will flash, and then return to the main interface, set the parameters of success!

5. In the main interface, press the DOWN key to achieve voltage and time switching.



Mode selection interface:


Press the SET button for a long time to enter the mode selection interface, set the finished, a long time press the SET button and then release the exit mode selection interface, back to the main interface.



Additional features:


1. Data upload: through the serial port to achieve data upload, interval 1s upload a voltage and run time, easy to post-data analysis;

2. Serial port settings parameters: You can set the mode and parameters through the serial port, more convenient;

3. An extra signal output, when the relay to meet the conditions, the output high, the other output low.

Serial port control (TTL level communication)

Communication standard:

The baud rate is 115200 bps

Data bits: 8

Stop bit: 1

Check digit: none

Flow control: none

Serial command:

"U-1": Operating mode (range U-1 to U-6)

"000": 0 - does not enable timing function, non-0 - enable timing function (range 001 to 999)

"Dw02.9": Set the lower limit voltage

"Up10.1": set the upper limit voltage (range 00.0V ~ 99.9V)

"Get": Get the current settings

"On": Allows the relay to turn on

"Off": Always turn off the relay

"Start": start uploading data

"Stop": stop uploading data

The above command can be any combination of two, need to be separated by commas

Such as: "dw02.9, up10.1" set the lower limit voltage 02.9V upper limit voltage 10.1V

Upload Status: Test Voltage + On Time + Status

"00.0V, 00: 00: 00, OP r n"

00.0V: Measured voltage

00:00:00: Relay on time

Status: OP relay on, CL relay off



STOP key function expansion:


Relay enable mode:

1. ON: OP conduction time, the relay allows conduction;

2. OFF: The relay is disabled and is always off;

Press the STOP button on the main interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is an emergency stop function, a key to disconnect the relay)

Sleep mode:

1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;

2. O-d normal mode: digital tube is always open display;

Press and hold the STOP button for 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.



Package include:


1u00d7Battery Charger Discharger Board

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

My Cart Cart (0)
My Favorites My Favorites (0)